| Single Phase – Low Voltage | ||||||||||||
| CAPACITY (KW) | 3KW 24V | 3KW 48V | 3.6KW 48V | 5KW 48V | 6KW 48V | |||||||
| MODEL NUMBER | VS-HY03S | VS-HY03S | VS-HY03S | VS-HY05S | VS-HY06S | |||||||
| BATTERY INPUT DATA | ||||||||||||
| Battery Type | Lead-acid or Lithium-lon | |||||||||||
| Battery Voltage Range (V) | 20~30 | 40~60 | ||||||||||
| Max. Charging Current (A) | 140 | 70 | 90 | 120 | 135 | |||||||
| Max. Discharging Current (A) | 140 | 70 | 90 | 120 | 135 | |||||||
| Charging Curve | 3 Stages / Equalization | |||||||||||
| Charging Strategy for Li-IonBattery | Self-adaption to BMS | |||||||||||
| PV STRING INPUT DATA | ||||||||||||
| Max. DC Input Power (W) | 3600 | 3600 | 4320 | 6000 | 7200 | |||||||
| Rated PV Input Voltage (V) | 370V | |||||||||||
| Voltage Operating Range (V) | 125~500V | |||||||||||
| Start-up Voltage (V) | 125 | |||||||||||
| MPPT Voltage Range (V) | 150-425 | |||||||||||
| Full Load DC Voltage Range (V) | 300-425 | |||||||||||
| PV Input Current (A) | 18 | 18+18 | ||||||||||
| Max. PV Isc Current (A) | 27 | 27+27 | ||||||||||
| Number of MPPT/Strings per MPPT | 1/1 | 2/1+1 | ||||||||||
| AC OUTPUT DATA | ||||||||||||
| Rated AC Output Power (W) | 3000 | 3600 | 5000 | 6000 | ||||||||
| Max. AC Output Power (W) | 3300 | 3690 | 5500 | 6600 | ||||||||
| AC Output Rated Current (A) | 13 | 15.7 | 21.7 | 26.1 | ||||||||
| Max. AC Output Current (A) | 15 | 18 | 25 | 30 | ||||||||
| Max. Continuous AC Passthrough Current (A) | 35 | 40 | ||||||||||
| Peak Power (off grid) | 2 time of rated power, 10 S | |||||||||||
| Power Factor | 0.9 leading to 0.9 lagging | |||||||||||
| Output Frequency and Voltage | 50/60Hz; L/N/PE 220/230Vac (single phase) | |||||||||||
| Grid Connection | Single Phase (L+N+PE) | |||||||||||
| DC injection current (mA) | <0.5%< IN | |||||||||||
| EFFICIENCY | ||||||||||||
| Max. Efficiency | 97.60% | |||||||||||
| Euro Efficiency | 97% | |||||||||||
| MPPT Efficiency | 99.90% | |||||||||||
| PROTECTION | ||||||||||||
| Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection | |||||||||||
| Output Over Voltage Protection | DC Type II/AC Type III | |||||||||||
| GENERAL DATA | ||||||||||||
| Operating Temperature Range (°C) | (-45°C ~ 60°C) | |||||||||||
| Cooling | Natural Cooling | Intelligent Cooling | ||||||||||
| Noise (dB) | ≤30db | |||||||||||
| Communication with BMS | RS485; CAN | |||||||||||
| Weight (kg) | 17.6 | 19.0 | ||||||||||
| Dimension excluding connectors & Brackets (mm) | 376W x 470H x 241D | |||||||||||
| Protection Degree | IP65 | |||||||||||
| Installation Style | Wall-mounted | |||||||||||
| Standard Warranty | 5 Years (Extendable upto 10 Years) | |||||||||||