| Single Phase – Low Voltage | ||||||||||||
| CAPACITY (KW) | 8KW 48V | 10KW 48V | ||||||||||
| MODEL NUMBER | VS-HY08S | VS-HY10T | ||||||||||
| BATTERY INPUT DATA | ||||||||||||
| Battery Type | Lead-acid or Lithium-lon | |||||||||||
| Battery Voltage Range (V) | 40~60 | |||||||||||
| Max. Charging Current (A) | 190 | 220 | ||||||||||
| Max. Discharging Current (A) | 190 | 220 | ||||||||||
| Charging Curve | 3 Stages / Equalization | |||||||||||
| Charging Strategy for Li-IonBattery | Self-adaption to BMS | |||||||||||
| PV STRING INPUT DATA | ||||||||||||
| Max. DC Input Power (W) | 9600 | 12000 | ||||||||||
| Rated PV Input Voltage (V) | 370V | |||||||||||
| Voltage Operating Range (V) | 125~500V | |||||||||||
| Start-up Voltage (V) | 125 | |||||||||||
| MPPT Voltage Range (V) | 150-425 | |||||||||||
| Full Load DC Voltage Range (V) | 300-425 | |||||||||||
| PV Input Current (A) | 26+26 | |||||||||||
| Max. PV Isc Current (A) | 34+34 | |||||||||||
| Number of MPPT/Strings per MPPT | 2/2+2 | |||||||||||
| AC OUTPUT DATA | ||||||||||||
| Rated AC Output Power (W) | 8000 | 10000 | ||||||||||
| Max. AC Output Power (W) | 8800 | 11000 | ||||||||||
| AC Output Rated Current (A) | 34.8 | 43.5 | ||||||||||
| Max. AC Output Current (A) | 40 | 50 | ||||||||||
| Max. Continuous AC Passthrough Current (A) | 50 | |||||||||||
| Peak Power (off grid) | 2 time of rated power, 10 S | |||||||||||
| Power Factor | 0.9 leading to 0.9 lagging | |||||||||||
| Output Frequency and Voltage | 50/60Hz; L/N/PE 220/230Vac (single phase) | |||||||||||
| Grid Connection | Single Phase (L+N+PE) | |||||||||||
| DC injection current (mA) | <0.5%< IN | |||||||||||
| EFFICIENCY | ||||||||||||
| Max. Efficiency | 97.60% | |||||||||||
| Euro Efficiency | 97% | |||||||||||
| MPPT Efficiency | 99.90% | |||||||||||
| PROTECTION | ||||||||||||
| Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge protection | |||||||||||
| Output Over Voltage Protection | DC Type II/AC Type III | |||||||||||
| GENERAL DATA | ||||||||||||
| Operating Temperature Range (°C) | (-45°C ~ 60°C) | |||||||||||
| Cooling | Intelligent Cooling | |||||||||||
| Noise (dB) | ≤30db | |||||||||||
| Communication with BMS | RS485; CAN | |||||||||||
| Weight (kg) | 35.6 | |||||||||||
| Dimensions (W*H*D) mm | 420W x 670H x 223D | |||||||||||
| Protection Degree | IP65 | |||||||||||
| Installation Style | Wall-mounted | |||||||||||
| Standard Warranty | 5 Years (Extendable upto 10 Years) | |||||||||||